Industrial Doors
Residential Garage Doors
Insulated steel sectional garage doors with remote operation, IP55 hardware and full counterbalance safety devices.
2 configurations
Industrial Doors/Garage Doors
Glazed aluminium sections where the opening is part of the elevation.
Industrial DoorsKey specifications
01Overview
An aluminium garage door is a sectional door built for appearance as much as function: aluminium sections with glazed inserts admit daylight and give the elevation a lighter, more architectural line than a solid steel leaf.
03Variants
The same product, built for a different job. Where a specification depends on opening dimensions, selected profile, operating duty or site conditions, the final configuration is confirmed during technical assessment.
Glazing across the full leaf, for showroom and display frontages where the opening is on view.
Foam-filled sections with selected glazed inserts, where thermal performance matters as well as daylight.
10Gallery





04Technical specifications
Technical data is shown first; features, applications, compatibility, installation, safety, ordering and downloads are a click away.
Clear opening between finished reveals.
Space above the opening for the barrel, stack or track.
Per side, for guides and drive.
Standard, high, vertical or low headroom — set by the building.
EN 12424.
EN 12425.
EN 12426.
EN 12428, for the complete door.
Duty, not torque, is what usually limits an operator.
Access control, traffic lights, alarm panel, interlocks.
EN 12453.
EN 13241 applies to industrial and garage doors in this market.
Required before any rating is published.
| Maximum clear widthClear opening between finished reveals. | Made to the opening; confirmed at survey |
|---|---|
| Maximum clear height | Made to the opening; confirmed at survey |
| Minimum headroom requiredSpace above the opening for the barrel, stack or track. | Confirmed at survey |
| Minimum side room requiredPer side, for guides and drive. | Confirmed at survey |
| Lift configurationStandard, high, vertical or low headroom — set by the building. | Set by the headroom available above the opening |
| Panel material | Aluminium sections with glazed inserts, foam filled |
|---|---|
| Panel thickness | Per the section chosen |
| Panel height | Per the section chosen |
| Insulation core | Foam fill (insulated panel variant) |
| Finish and colour | Powder coated or plastisol coated to any RAL colour |
| Glazing and vision panels | Glazed aluminium sections (full-vision) |
| Track and hardware | 2.5 mm galvanized steel, powder coated |
| Counterbalance | Torsion springs with wire-rope lifting cables |
| Perimeter sealing | Perimeter seals around the leaf |
| Wind load resistanceEN 12424. | EN 12424 |
|---|---|
| Water tightnessEN 12425. | Certification dependent — published against the certificate for the tested door |
| Air permeabilityEN 12426. | Certification dependent — published against the certificate for the tested door |
| Thermal transmittance (U)EN 12428, for the complete door. | Certification dependent — published against the certificate for the tested door |
| Airborne sound reduction | Certification dependent — published against the certificate for the tested door |
| Operator type | Electric operator |
|---|---|
| Rated motor power | Operator sized to the leaf at order |
| Supply voltage | 220 V / 380 V / 400 V |
| Duty ratingDuty, not torque, is what usually limits an operator. | Operator sized to the duty at order |
| Manual override | Manual release for hand operation during a power failure |
| Control system | Configuration dependent, per the operator selected |
|---|---|
| Activation devices | Configuration dependent |
| Travel limit setting | Set at commissioning |
| InterfacesAccess control, traffic lights, alarm panel, interlocks. | Configuration dependent |
| Spring-break device | Arrests the spring axis and cable if a spring fails |
|---|---|
| Anti-fall device | Arrests the leaf if a lifting cable breaks |
| Obstruction detection | Pneumatic (airbag) safety edge |
| Finger-trap protection | Per the section profile supplied |
| Operating force limitationEN 12453. | Certification dependent (EN 12453) |
| Manual release | Manual release for hand operation during a power failure |
| Product standardEN 13241 applies to industrial and garage doors in this market. | Certification dependent (EN 13241 field list) |
|---|---|
| Conformity marking | Certification dependent |
| Certificate referenceRequired before any rating is published. | Issued with the tested door; certification dependent |
| Protection class | IP55 |
|---|
Final specification depends on door dimensions, configuration, operating environment and project requirements.