A bi-parting automatic sliding glass door at a building entrance, two glazed leaves meeting at the centre between fixed side screens, with the operator header above carrying a motion sensor and the reception beyond visible through the glassEntrance Automation

Key specifications

Operation
Sensor activated, hands-free
Arrangements
Single leaf and bi-parting
Modes
Auto, partial, exit only, locked, hold open
Specification
Configured per opening at survey

* Final specification depends on door dimensions, configuration, operating environment and project requirements.

01Overview

About Automatic Sliding Glass Doors

An automatic sliding glass door is a pedestrian entrance driven by an operator concealed in a header above the opening. Motion and presence sensors on each side open the leaves as people approach and hold them open while anyone remains in the threshold.

03Variants

Available configurations

The same product, built for a different job. Where a specification depends on opening dimensions, selected profile, operating duty or site conditions, the final configuration is confirmed during technical assessment.

  • Single leaf

    One leaf sliding to one side. Suits narrower openings and lower footfall.

  • Bi-parting

    Two leaves parting from the centre. Clears the opening in roughly half the time, which matters at peak footfall.

  • Telescopic

    Nested leaves give a wider clear opening from a narrower overall frame — for openings where the structure limits the header width.

  • Break-out escape leaves

    Leaves swing out under push force to give a clear escape width. Required where the opening sits on a designated escape route.

10Gallery

Automatic Sliding Glass Doors in detail

  • A bi-parting automatic sliding glass door at an office lobby entrance seen from a three-quarter angle, the two framed glass leaves parted half open beneath the satin-silver header with its activation sensor, fixed side lights either side
  • Close-up of an automatic sliding glass door's meeting stile: the slim satin-silver aluminium frame profile with the toughened glass seated in its gasket, the vertical brush seal on the stile and the floor guide track below
  • The activation sensor of an automatic sliding glass door: a small black sensor unit with its dark lens mounted on the face of the satin-silver header above the sliding leaves
  • An office lobby entrance in the evening with the automatic sliding glass door parting as a person walks through hands-free, the framed glass leaves, header and side lights lit warmly from inside

04Technical specifications

Specification, features and ordering

Technical data is shown first; features, applications, compatibility, installation, safety, ordering and downloads are a click away.

Dimensions6 fields
Maximum clear width
Typically 700–3,000 mm single leaf and 900–3,000 mm bi-parting, depending on the operator

Clear opening between finished reveals.

Maximum clear height
Set by the leaf construction and the glazing; confirmed per project
Minimum headroom required
The operator header, typically 70–150 mm high depending on the operator

Space above the opening for the barrel, stack or track.

Minimum side room required
Side room equal to the leaf width for each leaf to park into; confirmed per project

Per side, for guides and drive.

Header depth and height
Typically 70–150 mm high and around 180–190 mm deep, depending on the operator
Maximum leaf weight
Typically up to 120–125 kg per leaf, or around 240 kg total, depending on the operator
Cycle performance4 fields
Opening speed
Up to about 0.7 m/s per leaf, adjustable
Closing speed
Up to about 0.7 m/s per leaf, adjustable; slowed on approach to the closed position
Hold-open time
Adjustable, typically 0–60 s; extends automatically for through traffic
Rated daily cycles
Continuous duty; operators are endurance tested to around 1,000,000 cycles by their manufacturers
Construction5 fields
Leaf arrangement
Single or bi-parting sliding leaves; telescopic arrangements where side room is short

Single, bi-parting or telescopic.

Glazing
Toughened or laminated safety glass in framed or frameless leaves, to the project specification
Frame and track
Aluminium header housing the drive, with roller carriages on a track and a floor guide at the threshold
Threshold detail
Flush floor guide as standard; recessed track or brush seals where specified
Finish
Anodised or powder-coated aluminium to match the facade, with RAL colour options
Drive5 fields
Operator type
Electromechanical sliding door operator with a DC motor driving a toothed belt
Rated motor power
Operator dependent; low-voltage DC drive
Supply voltage
230 V AC single phase 50 Hz to the operator
Duty rating
Continuous automatic operation; the operator adjusts to traffic
Manual override
Leaves can be moved by hand when the operator is switched off or on power failure
Control5 fields
Mode selector
Programme switch with automatic, permanent open, one-way, night and off modes; key-lockable on escape routes
Activation sensors
Radar motion detectors on each side; push button, key switch, access control or remote input
Presence sensors
Infrared light curtains protecting the main closing edge and the leaf travel path
Part-open width
Reduced opening width mode, set on commissioning, typically for winter or low-traffic use
Interfaces
Volt-free inputs and outputs for access control, fire alarm and building management; wireless or serial service interface on some operators
Safety and egress4 fields
Behaviour on power failure
Leaves free to move by hand; integral backup supply opens or closes the leaves automatically on operators fitted with it
Break-out leaves
Break-out leaves that swing outward under push are available for escape-route doorsets
Presence detection in the threshold
Light curtain across the threshold holds the leaves open while a person is in the opening
Escape route compliance
Where the door is on an escape route an operator type-tested for that use is specified, with backup opening or break-out leaves; the supplied operator's declaration applies

EN 16005.

Compliance3 fields
Product standard
Power-operated pedestrian doorsets fall under EN 16005; operators are type-tested by their manufacturers and the supplied operator's declaration applies

EN 16005 applies to power-operated pedestrian doorsets.

Conformity marking
As applicable to the supplied operator and market
Certificate reference
Operator manufacturer's type-test documentation for the supplied model; available on request

Final specification depends on door dimensions, configuration, operating environment and project requirements.

FAQ

Questions we are actually asked

What happens to an automatic door in a power cut?
It adopts the behaviour specified for that opening: released so it can be pushed open by hand, or driven open automatically. Which one is correct comes from the building's escape strategy, and is agreed before installation.
Are automatic doors suitable for an escape route?
Yes, with the right arrangement — typically break-out leaves that swing clear under push force, giving the full escape width.
How much clear opening do I need?
That comes from the footfall and the accessibility requirement rather than the door. Tell us both and we will size the leaves and the header around them.
Can the door be locked out of hours?
Yes — a mode selector gives automatic, partial, exit only, locked and hold open, and can be driven remotely from reception where the controller supports it.

Engineering enquiry

Get a specification for Automatic Sliding Glass Doors.