Skip to content
Standard Automatic Solutions Pvt. Ltd.

Fire & Safety Doors/Fire Rated Shutters

Fire Rated Rolling Shutters

Holding the compartment line where a large aperture cuts through it.

Fire rating is not published for this product. A rating applies to a tested assembly — curtain, guides, fixings, motor and release as installed — and only against a certificate for that assembly. Ask us and we will confirm what rating can be certified for your opening.

A steel rolling shutter descended across an opening in a concrete wall with fire visible in the compartment behind it, an alarm sounder and a sign reading fire rated door on the wall alongsideFire & Safety

Key specifications

Slat height
75 / 100 mm
Curtain thickness
25 mm
Sound reduction
21 dB
Fire rating
Certification dependent

* Final specification depends on door dimensions, configuration, operating environment and project requirements.

01Overview

About Fire Rated Rolling Shutters

A fire rated shutter closes an opening in a fire compartment wall. Its job is to hold that line for a stated period so the building's escape and containment strategy still works after a large aperture has been cut through a rated wall.

03Variants

Available configurations

The same product, built for a different job. Where a specification depends on opening dimensions, selected profile, operating duty or site conditions, the final configuration is confirmed during technical assessment.

  • Galvanised double-wall insulated

    The standard construction: galvanised double-wall slats with a silicon insulated strip, in steel guides.

  • Alarm-linked auto-close

    Interface to the fire alarm panel with a battery-backed release, so the shutter closes on alarm at a governed speed. Specified against the building's fire strategy.

10Gallery

Fire Rated Rolling Shutters in detail

  • A fire rated rolling shutter closed across a large opening in a concrete compartment wall inside an industrial building: flat galvanised double-skin slats, the curtain coil on an exposed barrel between bolted steel end plates, heavy galvanised guides, the side motor with hand chain, a control box and yellow-and-black bollards
  • Close-up at the base of a fire rated rolling shutter guide: the heavy galvanised angle guide anchored to the concrete wall with large bolts, the flat galvanised slats with riveted end locks entering the guide, and the angle-section bottom bar resting on the floor
  • A fire rated rolling shutter closed in a long concrete compartment wall dividing two production areas of a factory, with the curtain coil and end plates at the head, the side motor and chain, a control box, an alarm bell and a sprinkler pipe on the wall

04Technical specifications

Specification, features and ordering

Technical data is shown first; features, applications, compatibility, installation, safety, ordering and downloads are a click away.

Identification & material5 fields
Product family
Fire Rated Rolling Shutter
Material
Galvanized steel; certified fire-rated construction
Material grade
Certified configuration dependent
Coating
Galvanized
Surface treatment
Silver galvanized; customised where the certified system allows
Curtain8 fields
Construction
Galvanized double wall with silicon insulated strip
Profile
75 mm / 100 mm
Profile height
75 mm, 100 mm
Curtain thickness
25 mm
End lock
Configuration dependent
Slat weight
Certified configuration dependent
Curtain weight
Certified configuration dependent
Type code
FR75, FR100
Opening4 fields
Maximum width
Certified configuration dependent
Maximum height
Certified configuration dependent
Maximum area
Certified configuration dependent
Intermediate mullion
Certified configuration dependent
Guide7 fields
Guide material
Certified fire-rated guide construction, steel
Guide width
Certified configuration dependent
Guide depth
Certified configuration dependent
Guide thickness
Certified configuration dependent
Curtain engagement
Certified configuration dependent
Wind lock
Not applicable to the certified fire configuration unless specified
Guide seal
Certified configuration dependent
Barrel & shaft5 fields
Barrel type
Certified fire-rated barrel assembly
Shaft diameter
Certified configuration dependent
Shaft material
Steel
Bracket
Certified configuration dependent
Hood / headbox
Certified configuration dependent
Bottom4 fields
Bottom profile
Certified fire-rated bottom bar
Bottom bar dimensions
Certified configuration dependent
Bottom seal
Certified configuration dependent
Lock
Certified configuration dependent
Operation & control6 fields
Operation
Electric or manual
Motor options
Certified configuration dependent
Motor rating
Certified configuration dependent
Supply voltage
230 V AC single-phase or 415 V AC three-phase depending on the selected motor
Emergency manual override
Certified release mechanism with manual operation
Controls
Normal operation by push button or key switch; fire alarm interface available where specified
Performance7 fields
Wind resistance
Not applicable to the certified fire configuration unless separately tested
Fire rating
FD 120 / FD 180 / FD 240 according to the supplied certified configuration; the rating applies only to the tested system
Thermal performance
Certificate and test dependent
Acoustic performance
21 dB airborne sound reduction
Corrosion resistance
Galvanized surface protection
Cycle rating
Certified configuration dependent
Opening speed
Certified configuration dependent; controlled descent on release
Safety5 fields
Safety devices
Automatic fire-triggered closing where specified, fire alarm interface, certified release mechanism and manual release
Additional safety
Test standard, certificate reference and maximum tested opening are stated from the actual certificate for the supplied system
Anti-drop device
Certified configuration dependent
Brake
Certified configuration dependent
Obstacle detection
Certified configuration dependent
Finish2 fields
Finish
Silver galvanized; customised where the certified system allows
Colour
Silver or customised
Installation4 fields
Mounting
Face mounted, between jamb or recessed
Headroom required
Survey dependent
Side room required
Survey dependent
Mounting substrate
Structural opening prepared to the certified system requirement

Final specification depends on door dimensions, configuration, operating environment and project requirements.

Fire-rated performance applies only to tested and certified system configurations.

FAQ

Questions we are actually asked

What fire rating do these shutters carry?
We do not publish a rating against a product name. A rating belongs to a tested assembly — curtain, guides, fixings, motor and release, as installed — and we quote it only against a certificate covering that configuration. Tell us the opening and the required period and we will confirm what can be certified.
Which standard applies in India?
IS 3614 is the governing standard for metallic fire check doors, and BS 476 Part 22 and EN 1634-1 are commonly cross-referenced on projects. Where a rating is required, the certificate names the standard it was tested to.
Does the shutter close automatically in a fire?
Where the design requires it, yes — via an alarm interface or a fusible link, with controlled descent. The trigger and the behaviour are agreed with the fire strategy.
Can it be used as a normal shutter day to day?
Yes. It is operated conventionally in normal use; the fire function is a separate layer that takes priority on alarm.

Engineering enquiry

Get a specification for Fire Rated Rolling Shutters.

Five answers about the opening are usually enough for us to come back with a configuration and a price.

Loading enquiry form…

Get in touch

Or talk it through with an engineer.

If it is easier to describe the opening than to write it down, call or message us and we will work through it with you.

CallWhatsAppGet a quote