Skip to content
Standard Automatic Solutions Pvt. Ltd.

High Speed Doors/Controlled Environment High Speed Doors

High Speed Cleanroom / Hygiene Door

A high speed hygienic door for controlled production, pharmaceutical, healthcare and food-processing environments.

A royal-blue high speed roll-up hygiene door lowered to about two-thirds across an opening in the white flush-panel wall of a pharmaceutical clean corridor, its smooth seamless curtain hanging from the sloped-top stainless hood with a full-width clear vision band, held in fully enclosed brushed stainless guide columns with stainless bollards at their feet, the bright clean area and stainless equipment visible beneath the bottom bar, a stainless control station with red emergency stop beside the guide and a pale epoxy floorHigh Speed Doors

Product visualisations. These images are built to a written specification of this door type rather than photographed on site, and they are replaced as installation photography becomes available. They illustrate construction and arrangement; the figures that matter are in the specification below.

Key specifications

Construction
Sealed rapid-door assembly
Curtain
Hygienic PVC, cleanable surface
Frame and guides
Stainless steel / hygienic-coated
Dimensions
Project specific

* Final specification depends on door dimensions, configuration, operating environment and project requirements.

01Overview

About High Speed Cleanroom / Hygiene Door

In a controlled area the door is part of the room, not a fitting in it. This configuration is a sealed rapid-door assembly: a hygienic PVC curtain with a smooth, cleanable surface, running in stainless steel or hygienic-construction guide rails, in a stainless steel or hygienic-coated frame, with side and bottom seals at the perimeter.

03Variants

Available configurations

The same product, built for a different job. Where a specification depends on opening dimensions, selected profile, operating duty or site conditions, the final configuration is confirmed during technical assessment.

  • Stainless steel construction

    Stainless steel frame and guide rails, for areas washed down or cleaned with agents that painted and coated finishes do not survive.

  • Hygienic-coated construction

    Hygienic-coated frame and guide construction where the cleaning regime allows it and full stainless is not required.

10Gallery

High Speed Cleanroom / Hygiene Door in detail

  • Diagram of a high speed cleanroom door: a sealed rapid-door assembly in a stainless frame with side and bottom seals between two controlled rooms
  • Workers in protective suits inside a cleanroom
  • A worker filling trays on a food processing line

04Technical specifications

Specification, features and ordering

Technical data is shown first; features, applications, compatibility, installation, safety, ordering and downloads are a click away.

Dimensions1 fields
Maximum dimensions
Project specific
Performance2 fields
Opening speed
Application dependent
Closing speed
Application dependent
Construction6 fields
Door type
High Speed Cleanroom / Hygiene Door
Construction
Sealed rapid-door assembly
Curtain
Hygienic PVC / smooth cleanable surface
Frame
Stainless steel / hygienic-coated construction
Guide rails
Stainless steel / hygienic construction
Sealing
Side and bottom seals
Drive & control4 fields
Drive
Sized to the door at order

Operator type is not fixed for this line; it is selected against the opening and the duty.

Power
Configured to the site supply at order
Control enclosure
Hygienic / suitable IP-rated configuration
Activation
Radar / touchless sensor / push button
Safety1 fields
Safety
Photocells + safety edge
Options2 fields
Vision panel
Optional
Cleaning
Designed for routine cleaning/washdown where specified

Final specification depends on door dimensions, configuration, operating environment and project requirements.

FAQ

Questions we are actually asked

Where is a high speed hygiene door suitable?
Pharmaceutical manufacturing, healthcare facilities, food processing and manufacturing, laboratories, controlled production areas and other hygiene-sensitive environments — openings where the door has to maintain a separation rather than simply close.
What cleanroom classification can you achieve?
Classification is a property of the room and its air handling, not of the door alone, and none has been established for this door in isolation. We specify the door to suit the classification your cleanroom designer has set. We publish no class and no approval of any kind for the door on its own — if you need one, it has to be established for the assembly as installed, and we will tell you so rather than let a specification pass on an assumption.
What makes it hygienic rather than just a rapid door?
A hygienic PVC curtain with a smooth cleanable surface, stainless steel or hygienic-coated frame and guide construction, side and bottom seals, and a hygienic, suitably IP-rated control enclosure. It is designed for routine cleaning and washdown where that is specified.
What opening sizes are possible?
Maximum dimensions are project specific for this configuration. Send us the opening and the room requirement and we will confirm what is achievable rather than quoting a figure that may not apply to your installation.
How fast does it operate?
Opening and closing speeds are application dependent for this configuration. In a controlled area the speed is set by the pressure regime and the traffic, not by how fast the mechanism can be driven.
Which activation systems are available?
Radar, touchless sensor or push button. Touchless activation is usually preferred in a gowned area, because every touched surface is a procedure.
Can two doors be interlocked as an airlock?
Yes. A pair can be electrically interlocked so both are never open together. The override behaviour on fire alarm is agreed against the building escape strategy before commissioning rather than after.
What information do you need to quote?
Clear width and height of the opening, the headroom and side room available, roughly how many cycles a day it will take, whether it is internal or external, and what the two sides of the opening have to keep different from each other. Five answers and a photograph are usually enough for a configuration and a price.

Engineering enquiry

Get a specification for High Speed Cleanroom / Hygiene Door.

Five answers about the opening are usually enough for us to come back with a configuration and a price.

Loading enquiry form…

Get in touch

Or talk it through with an engineer.

If it is easier to describe the opening than to write it down, call or message us and we will work through it with you.

CallWhatsAppGet a quote