Rolling Shutters
Perforated Rolling Shutter
MS, GI or aluminium curtains perforated in fine, standard vision or heavy-duty patterns, for retail, malls and parking structures.
3 configurations
Rolling Shutters/Perforated, Vision & Grille Curtains
Security that still lets the shop front sell.
Rolling ShuttersProduct visualisations. These images are built to a written specification of this door type rather than photographed on site, and they are replaced as installation photography becomes available. They illustrate construction and arrangement; the figures that matter are in the specification below.
Key specifications
* Final specification depends on door dimensions, configuration, operating environment and project requirements.
01Overview
A vision shutter is a solid curtain with deliberate window sections set into it. That is a different intent from a perforated curtain: rather than a diffuse pattern across the whole area, you get a clear view through defined parts of the shutter and a solid curtain everywhere else.
03Variants
The same product, built for a different job. Where a specification depends on opening dimensions, selected profile, operating duty or site conditions, the final configuration is confirmed during technical assessment.
A medium viewing area set into an otherwise solid curtain. Vision section height and window pattern are configuration dependent.
Larger window and opening sections for greater visibility, where the storefront display is the priority.
A single curtain combining solid slats, perforated sections and vision or window sections, each positioned where it is needed on the opening.
10Gallery

04Technical specifications
Technical data is shown first; features, applications, compatibility, installation, safety, ordering and downloads are a click away.
| Product family | Vision / Window Rolling Shutter |
|---|---|
| Material | MS / GI / aluminium |
| Material grade | Selected according to the material chosen for the installation |
| Coating | Paint, powder coating or anodising depending on material |
| Surface treatment | Powder coating or anodising optional |
| Construction | Solid interlocking curtain with defined vision or window sections |
|---|---|
| Profile | Configuration dependent |
| Profile height | Configuration dependent |
| Slat thickness | Selected according to the material and profile |
| End lock | Configuration dependent |
| Slat weight | Calculated from the selected profile and material |
| Curtain weight | Calculated from the selected profile, material and opening dimensions |
| Vision section height | Configuration dependent |
| Window / opening pattern | Configuration dependent |
| Solid section | Solid interlocking slats outside the vision sections |
| Mixed curtain | Solid, perforated and vision sections can be combined in one curtain |
| Maximum width | Custom size; configuration dependent |
|---|---|
| Maximum height | Custom size; configuration dependent |
| Maximum area | Configuration dependent |
| Intermediate mullion | Available for large or multiple curtain arrangements |
| Guide material | Material and size selected according to the curtain |
|---|---|
| Guide width | 65 / 75 / 100 mm class depending on opening size |
| Guide depth | Configuration dependent; conventional systems approximately 65–100 mm class |
| Guide thickness | 3.15 mm class conventional guide construction |
| Curtain engagement | 40–60 mm depending on opening width |
| Wind lock | Optional; required where wind exposure or design demands it |
| Guide seal | Optional; configuration dependent |
| Barrel type | Conventional or motorised barrel according to configuration |
|---|---|
| Shaft diameter | 32 / 40 / 50 mm class, selected according to shutter width and curtain load |
| Shaft material | Steel |
| Bracket | Steel bracket, size selected according to shutter height and load; conventional reference range from 300 × 300 mm upward |
| Hood / headbox | Hood or headbox to suit the material; size configuration dependent |
| Bottom profile | Bottom rail to suit the curtain material |
|---|---|
| Bottom bar dimensions | Configuration dependent |
| Bottom seal | Optional rubber or EPDM seal where required |
| Lock | Central or side locking according to configuration |
| Operation | Manual or gear operated; motorised recommended for larger and mixed curtains |
|---|---|
| Motor options | Tubular, central or side-mounted motor depending on shutter size and configuration |
| Motor rating | Selected according to curtain weight, opening size, barrel and duty cycle |
| Supply voltage | 230 V AC single-phase or 415 V AC three-phase depending on the selected motor |
| Emergency manual override | Manual override available on powered configurations |
| Controls | Push button, key switch, RF remote, access control, GSM or Wi-Fi where compatible |
| Wind resistance | Configuration dependent |
|---|---|
| Fire rating | Not fire-rated unless supplied as a certified fire-rated system |
| Thermal performance | Not rated |
| Acoustic performance | Configuration dependent |
| Corrosion resistance | Depends on the material and finish selected |
| Cycle rating | Duty dependent; the operator is selected according to operating frequency |
| Opening speed | Motor and configuration dependent |
| Safety devices | Photocell, safety edge and emergency stop available depending on the motor and control configuration |
|---|---|
| Anti-drop device | Available where required; configuration dependent |
| Brake | Motor or gear brake according to the selected operator |
| Obstacle detection | Available with a compatible control and safety system |
| Finish | Paint, powder coating or anodising depending on material |
|---|---|
| Colour | Standard colours; custom RAL available |
| Mounting | Face mounted, between jamb or recessed |
|---|---|
| Headroom required | Survey dependent |
| Side room required | Survey dependent |
| Mounting substrate | Masonry, RCC, structural steel or other suitable structural support; fixing selected according to the substrate |
Specifications may vary according to opening dimensions, selected profile, material, operating method, site conditions and final system configuration.
FAQ
Engineering enquiry
Five answers about the opening are usually enough for us to come back with a configuration and a price.

Get in touch
If it is easier to describe the opening than to write it down, call or message us and we will work through it with you.